-40%

XITRON 2000MN DCV-DCA THERMOCOUPLE V/A/T CALIBRATOR

$ 211.17

Availability: 10 in stock
  • Brand: XiTron Technologies
  • Item must be returned within: 30 Days
  • Condition: Used
  • MPN: 2000MN
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • All returns accepted: Returns Accepted

    Description

    XITRON 2000MN DCV-DCA THERMOCOUPLE V/A/T CALIBRATOR
    Used, as shown. Powers up.
    Comes with:
    -
    XITRON 2000MN unit
    -Case
    -Case strap
    -Power adapter
    -Power Cord
    -Manual *10 units do not have manuals.
    -CD *10 do not have CD's.
    -One of 25 has a white face as opposed to blue.. if that matters.
    From manufacturer:
    Xitron 2000MN DCV-DCA Thermocouple Calibrator-Simulator for Process Control Calibration
    The Xitron 2000MN DCV-DCA Thermocouple Calibrator-Simulator performs process loop calibration.
    Its capabilities also include the generation of precision bipolar ±DC Voltages and currents.
    Additionally, the unit both accurately measures as well as simulates thermocouples.
    Enablement of the calibration of the 4-20ma-loop uses scaling factors, offset factors and “unit” text strings.
    Although the RS 232 Interface is standard, the optional IEEE-488 isolated interface further enhances this instrument.
    The combination of HCMOS microprocessor technologies with low-power precision analog circuitry yields a long battery life.
    Automatic internal calibration and simple front panel (covers on) external calibration maintain high accuracy. A comprehensive range of computational abilities enable a variety of applications. The Xitron 2000IN preforms calibration in PPM rather than percent for increased calibration accuracy.
    Xitron 2000MN Reads and Sources Thermocouples in in ºC or ºF
    The Xitron 2000MN DCV-DCA Thermocouple Calibrator Simulator provides temperature measurement and automatic cold junction compensation. It additionally allows the user to read or source in ºC or ºF for B/E/J/K/N/R/S and T thermocouples.
    Xitron 2000MN DCV-DCA Thermocouple Calibrator-Simulator Features
    Fully bi-polar DC voltage and current capability; 22V, 10 ppm accuracy, 22mA, 40 ppm accuracy
    Also Temperature simulation with 0.01° resolution, 0.03° – 0.06° accuracy
    Temperature measurement with 0.1° – 0.2° accuracy
    Auto cold junction compensation.
    Additionally, Battery/line operation
    Excellent performance and flexibility in portable, battery-operated applications
    DC voltage as well as current capability,+/- 22 volt, 10ppm accuracy,+/- 22mA, 40-ppm accuracy
    Temperature simulation with 0.01º resolution as well as 0.015º-0.12º accuracy (90 day)
    DC resolution down to 10nV or 10pA
    Temperature measurement with 0.1º-0.2º accuracy (90 day)
    Auto cold junction compensation
    NiMH battery operation (8 hours typ.)
    Temperature control loops
    Thermocouple measurement as well as simulation
    Also, Battery status indication
    Standard RS232 interface allows laptop PC control in the field
    Optional IEEE-488 interface supports ATE applications
    Additional memory available to interface for 10 user-defined test steps
    No further testing could be conducted however; there are no visible defects that would impede normal function.
    E-bay Required Medical Disclaimer:
    By purchasing, buyer is stating they are not prohibited from purchase, ownership, or possession of item. Buyer attests they are a physician, licensed healthcare practitioner, or any other practitioner licensed by the law of the State in which the practitioner practices to use or order the use of the device.
    "The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."
    All items are sold new or used, as-is unless stated otherwise. We do not offer or imply any guarantees or warranties on any equipment sold. It is the responsibility of the buyer to thoroughly inspect by qualified technicians before putting equipment in service.  We accept no liability for equipment once it has left our warehouse.
    Please note most of the medical equipment pieces need some maintenance and recertification. It is normal and legal requirement. We strongly recommend that you get proper certification prior to use and get the unit completely checked out.
    Rubber tubing, seals and such items often need to be replaced on a routinely basis for preventive maintenance on a lot of different types of equipment.  It is recommended that they be replaced as per need basis.
    Item has been cleaned and handled in accordance with the manufacturer's instructions.
    Dalma Corp
    New Orleans, LA
    800 816 9858
    Listing and template services provided by inkFrog